Dave H.
Dave H. Checked in
Replaced painted sprinkler head in 108 closet
Gresham, OR 97030
Dave H.
Dave H. Checked in
REPLACED PAINTED SPRINKLER HEAD
Portland, OR 97233
Dave H.
Dave H. Checked in
Replace head from fire, swap 3 EXTINGUISHERS
Portland, OR 97233
Steven M.
Steven M. Checked in
Emergency Call
Portland, OR 97233
Dave H.
Dave H. Checked in
Building D painted heads replaced
Troutdale, OR 97060
Tony P.
Tony P. Checked in
5 year internal sprinkler maintenance
Portland, OR 97230
Dave H.
Dave H. Checked in
Flow test hydrant
Gresham, OR 97080
Tony P.
Tony P. Checked in
Annual Fire Alarm Inspection
Portland, OR 97236
Justin C.
Justin C. Checked in
Annual backflow
Vancouver, WA 98660
Tony P.
Tony P. Checked in
Annual alarm inspection
Portland, OR 97211
Justin C.
Justin C. Checked in
Conducted semi-annual inspection of commercial kitchen fire suppression system per NFPA 17A. Verified proper alignment of nozzles over cooking appliances. Checked fusible links for integrity and correct temperature rating. Examined agent distribution piping for obstructions. Tested manual pull station and automatic fuel shut-off. Confirmed adequate agent supply in cylinder, weighing to ensure within 5% of capacity. Inspected pressure gauge, ensuring 100-250 PSI operating range. Updated system tag and provided detailed report to kitchen manager, recommending replacement of two deteriorated flex connectors.
Vancouver, WA 98662
Steven M.
Steven M. Checked in
Performed annual fire extinguisher inspection as per NFPA 10 standards. Examined 30 units, including ABC dry chemical, CO2, and Class K types. Verified proper operating pressure: 195-205 PSI for ABC, 800-900 PSI for CO2. Checked for physical damage, corrosion, and obstructions in nozzles and hoses. Ensured clear visibility and appropriate signage for all units. Conducted breakdown and internal inspection on 5 extinguishers due for 6-year maintenance. Replaced one unit with expired hydrostatic test date. Updated inspection tags and provided comprehensive report to facility manager, detailing findings and recommendations for strategic placement optimization.
Ridgefield, WA 98642
Paul W.
Paul W. Checked in
Conducted an annual fire extinguisher inspection. Verified pressure levels, checked for physical damage, and ensured seals were intact. Examined expiration dates and replaced any outdated units. Confirmed proper mounting and accessibility of extinguishers. This thorough inspection ensures all fire extinguishers meet safety standards and are ready for immediate use.
Hillsboro, OR 97124
TOBY F.
TOBY F. Checked in
Completed follow-up inspection on previously identified fire safety deficiencies. Re-examined five fire doors with faulty self-closing mechanisms. Verified installation of new door closers rated for 15-20 lbs closing force. Tested emergency lighting units, confirming 90-minute battery backup capacity. Inspected newly installed fire stops in cable penetrations, ensuring proper intumescent material application. Reassessed sprinkler head obstructions, confirming minimum 18-inch clearance restored. Evaluated updated fire evacuation plans for compliance with NFPA 101 requirements. Documented all corrective actions in comprehensive report, noting full compliance achieved. Recommended quarterly self-inspections to facility manager for ongoing fire safety maintenance.
Clackamas, OR 97015
Steven M.
Steven M. Checked in
Inspected each extinguisher for proper pressure, intact safety seals, and physical integrity. Checked for expiration dates and replaced any expired units. Refilled and recharged extinguishers as necessary, adhering to NFPA 10 standards. Ensured correct mounting and accessibility of all extinguishers. This service guarantees that all fire extinguishers are fully operational, compliant with safety regulations, and ready for immediate use in an emergency.
Vancouver, WA 98686
Ray T.
Ray T. Checked in
Executed quarterly fire alarm system inspection per NFPA 72 guidelines. Tested all initiating devices, including smoke detectors, heat detectors, and manual pull stations. Verified proper operation of notification appliances, ensuring minimum 75 dBA at pillow level in sleeping areas. Checked battery backup, confirming 24-hour standby and 5-minute alarm capacity. Inspected fire alarm control panel for trouble signals and ground faults. Tested central station communication using both primary and secondary pathways. Verified correct annunciation of zone information. Documented all findings in logbook and provided detailed report to building management, recommending replacement of two outdated smoke detectors.
Portland, OR 97220
Patrick P.
Patrick P. Checked in
Sprinkler inspection
Hillsboro, OR 97124
Tony P.
Tony P. Checked in
Quarterly pull station inspection
Portland, OR 97219
TOBY F.
TOBY F. Checked in
Cabinet Repair
Portland, OR 97214
Eric C.
Eric C. Checked in
Urgent call for dry valve reset
Portland, OR 97202
Dave H.
Dave H. Checked in
FLOW TEST HYDRANT
Gresham, OR 97080
LUKE L.
LUKE L. Checked in
.
Vancouver, WA 98682
Ariel C.
Ariel C. Checked in
Annual fire extinguisher service
Portland, OR 97217
Ariel C.
Ariel C. Checked in
Annual fire sprinkler inspection Annual Backflow test
Portland, OR 97217
Ray T.
Ray T. Checked in
Troubleshooting
Portland, OR 97218